Science Format Description - includes all science data; housekeeping data repeats on a major frame basis (every 16 seconds), so the housekeeping data that appears in each minor frame in a major frame is different. Only a subset of the Star Tracker data is included - each major frame includes data from one star, with the four brightest stars outputed over 4 sucessive major frames.
Version 9/8/95
-------------- ------ -------------------------------------------------------------------------------- ---------Science Format Minor Frame 0 Location Length Parameter Source -------------- ------ -------------------------------------------------------------------------------- --------- 0 32 Sync Word C&DH 32 48 Virtual Channel Header C&DH 80 48 Packet Header C&DH 128 32 Packet Secondary Header C&DH 160 4 Format ID C&DH -------------- ------ -------------------------------------------------------------------------------- --------- 164 2 Spare C&DH 166 2 C&DH ID C&DH 168 1 Collection Format C&DH 169 3 Major Frame Count C&DH 172 4 Minor Frame Count C&DH -------------- ------ -------------------------------------------------------------------------------- --------- 176 8 Selectable Telemetry Byte C&DH 184 16 Phase Angle latched in collected minor frame 0 C&DH 200 8 Propellant Tank A1 Temperature DCM2-AD12 208 8 Propellant Tank A2 Temperature DCM2-AD13 216 8 Propellant Tank B1 Temperature DCM2-AD14 -------------- ------ -------------------------------------------------------------------------------- --------- 224 8 Propellant Tank B2 Temperature DCM2-AD15 232 8 Internal Lines A Temperature DCM2-AD16 240 8 Internal Lines B Temperature DCM2-AD17 248 8 External Lines +X Temperature DCM2-AD18 256 8 External Lines -X Temperature DCM2-AD19 -------------- ------ -------------------------------------------------------------------------------- --------- 264 8 Star Tracker Temperature: Near Base DCM2-AD20 272 8 Instrument Deck Temp: Near Center by SEPICA I/F DCM2-AD22 280 8 Instrument Deck Temp: Near ULEIS Elec Box DCM2-AD23 288 8 Instrument Deck Temp: Near EPAM I/F and -X Edge DCM2-AD24 296 8 Instrument Deck Temp: Near +Y/-X Edge DCM2-AD25 -------------- ------ -------------------------------------------------------------------------------- --------- Science Format Minor Frame 0 Location Length Parameter Source -------------- ------ -------------------------------------------------------------------------------- --------- 304 8 "Instr Deck Temp: Near +X/+Y Edge, By SWICS I/F" DCM2-AD26 312 8 "Instrument Deck Temp: Near MFI, S3DPU, & SIS I/F" DCM2-AD27 320 8 Instrument Deck Temperature: Near -Y Edge DCM2-AD28 328 8 "Instrument Deck Temp: Near +X Edge, By Pylon" DCM2-AD29 336 24 "Last SP TT = 4 Mnr Frame bits, 10 subsec count bits, 2 ID bits, 8 Y-angle bits" C&DH -------------- ------ -------------------------------------------------------------------------------- --------- 360 304 Magnetometer Data DCM2-SD3 664 168 EPAM Data DCM1-SD0 832 464 CRIS Data DCM2-SD0 1296 1992 SIS Data DCM2-SD1 3288 544 SWEPAM Ion Data DCM1-SD2 -------------- ------ -------------------------------------------------------------------------------- --------- 3832 456 SWEPAM Electron Data DCM2-SD2 4288 1000 ULEIS Data DCM1-SD1 5288 1624 S^3 DPU Data DCM1-SD3 6912 32 Command Link Control Word C&DH 6944
-------------- ------ ------------------------------------------------------ --------------Science Format Minor Frame 1 Location Length Parameter Source -------------- ------ ------------------------------------------------------ -------------- 0 32 Sync Word C&DH 32 48 Virtual Channel Header C&DH 80 48 Packet Header C&DH 128 32 Packet Secondary Header C&DH 160 4 Format ID C&DH -------------- ------ ------------------------------------------------------ -------------- 164 2 Spare C&DH 166 2 C&DH ID C&DH 168 1 Collection Format C&DH 169 3 Major Frame Count C&DH 172 4 Minor Frame Count C&DH -------------- ------ ------------------------------------------------------ -------------- 176 8 Selectable Telemetry Byte C&DH 184 16 Phase Angle latched in collected minor frame 1 C&DH 200 8 Heater-S/C Specific Xpdr & Shunt I/F Current DCM2-DIFA13 208 8 "Sun Sensor (-X/-Y) Temp: Side of Brack, Near Sensor" DCM2-AD21 216 8 +X Solar Array Panel Temperature DCM2-PT0 -------------- ------ ------------------------------------------------------ -------------- 224 8 +X Solar Array Panel Hinge Temp: Near -Y DCM2-PT1 232 8 -X Solar Array Panel Temperature DCM2-PT2 240 8 -X Solar Array Panel Hinge Temp: Near +Y DCM2-PT3 248 8 Magnetometer Inboard Temperature DCM2-SEA15 256 8 Magnetometer Outboard Temperature DCM2-SEA16 -------------- ------ ------------------------------------------------------ -------------- 264 8 Magnetometer Inboard Heater Power Level DCM2-SEA17 272 8 Magnetometer Outboard Heater Power Level DCM2-SEA18 280 8 S3 DPU Power Converter Voltage DCM2-SEA19 288 8 Power Subsystem Processor A Current DCM2-DIFA22 296 8 Power Subsystem Processor B Current DCM2-DIFA23 -------------- ------ ------------------------------------------------------ -------------- Science Format Minor Frame 1 Location Length Parameter Source -------------- ------ ------------------------------------------------------ -------------- 304 8 Prop. System Axial Thruster Current DCM2-DIFA24 312 8 DCM2 - 0-50mV Channel #25 (pre-wired for 2A on TB) DCM2-DIFA25 320 8 Heater-S/C Surv. Panel Htr Current DCM2-DIFA26 328 8 DCM2 - 0-5V Channel #20 DCM2-SEA20 336 8 Instrument Deck Temperature (TBD) #2 DCM2-AD30 -------------- ------ ------------------------------------------------------ -------------- 344 1 DCM2 - Digital Telltale-Logic Channel #7 DCM2-DIGTTLOG7 345 1 DCM2 - Digital Telltale-Logic Channel #6 DCM2-DIGTTLOG6 346 1 DCM2 - Digital Telltale-Logic Channel #5 DCM2-DIGTTLOG5 347 1 DCM2 - Digital Telltale-Logic Channel #4 DCM2-DIGTTLOG4 348 1 DCM2 - Digital Telltale-Logic Channel #3 DCM2-DIGTTLOG3 -------------- ------ ------------------------------------------------------ -------------- 349 1 DCM2 - Digital Telltale-Logic Channel #2 DCM2-DIGTTLOG2 350 1 DCM2 - Digital Telltale-Logic Channel #1 DCM2-DIGTTLOG1 351 1 DCM2 - Digital Telltale-Logic Channel #0 DCM2-DIGTTLOG0 352 1 SEPICA Gas Valve Telltale DCM2-DIGTTSW15 353 1 DCM2 - Digital Telltale-Switch Channel #14 DCM2-DIGTTSW14 -------------- ------ ------------------------------------------------------ -------------- 354 1 DCM2 - Digital Telltale-Switch Channel #13 DCM2-DIGTTSW13 355 1 DCM2 - Digital Telltale-Switch Channel #12 DCM2-DIGTTSW12 356 1 DCM2 - Digital Telltale-Switch Channel #11 DCM2-DIGTTSW11 357 1 DCM2 - Digital Telltale-Switch Channel #10 DCM2-DIGTTSW10 358 1 DCM2 - Digital Telltale-Switch Channel #9 DCM2-DIGTTSW9 -------------- ------ ------------------------------------------------------ -------------- 359 1 DCM2 - Digital Telltale-Switch Channel #8 DCM2-DIGTTSW8 360 304 Magnetometer Data DCM2-SD3 664 168 EPAM Data DCM1-SD0 832 464 CRIS Data DCM2-SD0 1296 1992 SIS Data DCM2-SD1 -------------- ------ ------------------------------------------------------ -------------- Science Format Minor Frame 1 Location Length Parameter Source -------------- ------ ------------------------------------------------------ -------------- 3288 544 SWEPAM Ion Data DCM1-SD2 3832 456 SWEPAM Electron Data DCM2-SD2 4288 1000 ULEIS Data DCM1-SD1 5288 1624 S^3 DPU Data DCM1-SD3 6912 32 Command Link Control Word C&DH -------------- ------ ------------------------------------------------------ -------------- 6944
-------------- ------ ------------------------------------------------------- ---------Science Format Minor Frame 2 Location Length Parameter Source -------------- ------ ------------------------------------------------------- --------- 0 32 Sync Word C&DH 32 48 Virtual Channel Header C&DH 80 48 Packet Header C&DH 128 32 Packet Secondary Header C&DH 160 4 Format ID C&DH -------------- ------ ------------------------------------------------------- --------- 164 2 Spare C&DH 166 2 C&DH ID C&DH 168 1 Collection Format C&DH 169 3 Major Frame Count C&DH 172 4 Minor Frame Count C&DH -------------- ------ ------------------------------------------------------- --------- 176 8 Selectable Telemetry Byte C&DH 184 16 Phase Angle latched in collected minor frame 2 C&DH 200 8 Aft Deck Temperature: Center of Deck DCM2-PT19 208 8 Aft Deck Temperature: Between Transponders DCM2-PT20 216 8 Aft Deck Temperature: Near +X Low Gain Ant Base DCM2-PT21 -------------- ------ ------------------------------------------------------- --------- 224 8 Aft Deck Temperature: +X/+Y Edge DCM2-PT22 232 8 "Aft Deck Temp: +Y/-X Edge, Near Low Gain Ant Base" DCM2-PT23 240 8 "+X Side Panel Temp #1: ~1.5"" from Bottom Center" DCM2-PT4 248 8 "+X Side Panel Temp #2: ~1.5"" from Top Center" DCM2-PT5 256 8 "+X/+Y Side Panel Temp #1: Bot, Left of Umbilical" DCM2-PT6 -------------- ------ ------------------------------------------------------- --------- 264 8 "+Y Side Panel Temp #1: ~1.5"" from Bottom Center" DCM2-PT7 272 8 "+Y Side Panel Temp #2: ~1.5"" from Top Center" DCM2-PT8 280 8 "+Y/-X Side Panel Temp #1: ~1.5"" from Bottom Center" DCM2-PT9 288 8 "-X Side Panel Temp #1: ~1.5"" from Bottom Center" DCM2-PT10 296 8 "-X/-Y Side Panel Temp #1: ~1.5"" from Bottom Center" DCM2-PT11 -------------- ------ ------------------------------------------------------- --------- Science Format Minor Frame 2 Location Length Parameter Source -------------- ------ ------------------------------------------------------- --------- 304 8 -Y Side Panel Temp #1: Near Bottom Center DCM2-PT12 312 8 "-Y/+X Side Panel Temp #1: ~1.5"" from Bottom Center" DCM2-PT13 320 8 "+Y Boom Temp: Near Mag Sensor, Use Long Leads" DCM2-PT14 328 8 "+Y Mag I/F Temp: On Sensor Base, Use Long Leads" DCM2-PT15 336 8 "-Y Mag I/F Temp: On Sensor Base, Use Long Leads" DCM2-PT16 -------------- ------ ------------------------------------------------------- --------- 344 8 Antenna Dish Temperature: Located Near ~R/2 DCM2-PT17 352 8 "+Y Fwd Low Gain Ant: Pylon Below Ant, Long Leads" DCM2-PT18 360 304 Magnetometer Data DCM2-SD3 664 168 EPAM Data DCM1-SD0 832 464 CRIS Data DCM2-SD0 -------------- ------ ------------------------------------------------------- --------- 1296 1992 SIS Data DCM2-SD1 3288 544 SWEPAM Ion Data DCM1-SD2 3832 456 SWEPAM Electron Data DCM2-SD2 4288 1000 ULEIS Data DCM1-SD1 5288 1624 S^3 DPU Data DCM1-SD3 -------------- ------ ------------------------------------------------------- --------- 6912 32 Command Link Control Word C&DH 6944
-------------- ------ --------------------------------------------------- -----------Science Format Minor Frame 3 Location Length Parameter Source -------------- ------ --------------------------------------------------- ----------- 0 32 Sync Word C&DH 32 48 Virtual Channel Header C&DH 80 48 Packet Header C&DH 128 32 Packet Secondary Header C&DH 160 4 Format ID C&DH -------------- ------ --------------------------------------------------- ----------- 164 2 Spare C&DH 166 2 C&DH ID C&DH 168 1 Collection Format C&DH 169 3 Major Frame Count C&DH 172 4 Minor Frame Count C&DH -------------- ------ --------------------------------------------------- ----------- 176 8 Selectable Telemetry Byte C&DH 184 16 Phase Angle latched in collected minor frame 3 C&DH 200 8 Center of +X Side Panel: Betw Battery and Term Bds DCM2-AD6 208 8 C&DH A Converter Voltage DCM2-SEA0 216 8 C&DH B Converter Voltage DCM2-SEA1 -------------- ------ --------------------------------------------------- ----------- 224 8 C&DH Component A Current DCM2-DIFA0 232 8 C&DH Component B Current DCM2-DIFA1 240 8 C&DH Component Oscillator Temp (not x-strapped) DCM2-AD9 248 8 "C&DH Component A Temp: Outside of Box, Near Base" DCM2-AD7 256 8 "C&DH Component B Temp: Outside of Box, Near Base" DCM2-AD8 -------------- ------ --------------------------------------------------- ----------- 264 8 Heater-Spacecraft Aft and Forward Survival Current DCM2-DIFA17 272 8 Heater-Spacecraft Operational Current DCM2-DIFA18 280 8 Main Bus Current DCM2-SEA2 288 8 Main Bus Voltage DCM2-SEA3 296 8 PSE Analog Shunt Current DCM2-DIFA19 -------------- ------ --------------------------------------------------- ----------- Science Format Minor Frame 3 Location Length Parameter Source -------------- ------ --------------------------------------------------- ----------- 304 8 Star Tracker Current DCM2-DIFA8 312 8 Power Sw Comp. Partial Side A + Side B Current #1 DCM2-DIFA2 320 8 Power Sw Comp. Partial Side A + Side B Current #2 DCM2-DIFA3 328 8 Ordnance Fire Comp. Side A + Side B Current #1 DCM2-DIFA4 336 8 Ordnance Fire Comp. Side A + Side B Current #2 DCM2-DIFA5 -------------- ------ --------------------------------------------------- ----------- 344 8 DSAD A Current DCM2-DIFA20 352 8 DSAD B Current DCM2-DIFA21 360 304 Magnetometer Data DCM2-SD3 664 168 EPAM Data DCM1-SD0 832 464 CRIS Data DCM2-SD0 -------------- ------ --------------------------------------------------- ----------- 1296 1992 SIS Data DCM2-SD1 3288 544 SWEPAM Ion Data DCM1-SD2 3832 456 SWEPAM Electron Data DCM2-SD2 4288 1000 ULEIS Data DCM1-SD1 5288 1624 S^3 DPU Data DCM1-SD3 -------------- ------ --------------------------------------------------- ----------- 6912 32 Command Link Control Word C&DH 6944
-------------- ------ ---------------------------------------------- ----------Science Format Minor Frame 4 Location Length Parameter Source -------------- ------ ---------------------------------------------- ---------- 0 32 Sync Word C&DH 32 48 Virtual Channel Header C&DH 80 48 Packet Header C&DH 128 32 Packet Secondary Header C&DH 160 4 Format ID C&DH -------------- ------ ---------------------------------------------- ---------- 164 2 Spare C&DH 166 2 C&DH ID C&DH 168 1 Collection Format C&DH 169 3 Major Frame Count C&DH 172 4 Minor Frame Count C&DH -------------- ------ ---------------------------------------------- ---------- 176 8 Selectable Telemetry Byte C&DH 184 16 Phase Angle latched in collected minor frame 4 C&DH 200 144 Data Recorder A Hskp Data DCM2-SD4 344 8 Solid State Recorder A PWRTEMP DCM2-AD10 352 8 Data Recorder A Current DCM2-DIFA6 -------------- ------ ---------------------------------------------- ---------- 360 304 Magnetometer Data DCM2-SD3 664 168 EPAM Data DCM1-SD0 832 464 CRIS Data DCM2-SD0 1296 1992 SIS Data DCM2-SD1 3288 544 SWEPAM Ion Data DCM1-SD2 -------------- ------ ---------------------------------------------- ---------- 3832 456 SWEPAM Electron Data DCM2-SD2 4288 1000 ULEIS Data DCM1-SD1 5288 1624 S^3 DPU Data DCM1-SD3 6912 32 Command Link Control Word C&DH 6944
-------------- ------ ---------------------------------------------- ----------Science Format Minor Frame 5 Location Length Parameter Source -------------- ------ ---------------------------------------------- ---------- 0 32 Sync Word C&DH 32 48 Virtual Channel Header C&DH 80 48 Packet Header C&DH 128 32 Packet Secondary Header C&DH 160 4 Format ID C&DH -------------- ------ ---------------------------------------------- ---------- 164 2 Spare C&DH 166 2 C&DH ID C&DH 168 1 Collection Format C&DH 169 3 Major Frame Count C&DH 172 4 Minor Frame Count C&DH -------------- ------ ---------------------------------------------- ---------- 176 8 Selectable Telemetry Byte C&DH 184 16 Phase Angle latched in collected minor frame 5 C&DH 200 144 Data Recorder B Hskp Data DCM2-SD5 344 8 Solid State Recorder B PWRTEMP DCM2-AD11 352 8 Data Recorder B Current DCM2-DIFA7 -------------- ------ ---------------------------------------------- ---------- 360 304 Magnetometer Data DCM2-SD3 664 168 EPAM Data DCM1-SD0 832 464 CRIS Data DCM2-SD0 1296 1992 SIS Data DCM2-SD1 3288 544 SWEPAM Ion Data DCM1-SD2 -------------- ------ ---------------------------------------------- ---------- 3832 456 SWEPAM Electron Data DCM2-SD2 4288 1000 ULEIS Data DCM1-SD1 5288 1624 S^3 DPU Data DCM1-SD3 6912 32 Command Link Control Word C&DH 6944
-------------- ------ ---------------------------------------------- -----------Science Format Minor Frame 6 Location Length Parameter Source -------------- ------ ---------------------------------------------- ----------- 0 32 Sync Word C&DH 32 48 Virtual Channel Header C&DH 80 48 Packet Header C&DH 128 32 Packet Secondary Header C&DH 160 4 Format ID C&DH -------------- ------ ---------------------------------------------- ----------- 164 2 Spare C&DH 166 2 C&DH ID C&DH 168 1 Collection Format C&DH 169 3 Major Frame Count C&DH 172 4 Minor Frame Count C&DH -------------- ------ ---------------------------------------------- ----------- 176 8 Selectable Telemetry Byte C&DH 184 16 Phase Angle latched in collected minor frame 6 C&DH 200 128 Power Subsystem Primary Proc. Data- 2x Major DCM2-SD6 328 8 -Y Side Panel: Near PSDE DCM2-AD4 336 8 -X Side Panel: Near Digital Shunt Box DCM2-AD5 -------------- ------ ---------------------------------------------- ----------- 344 8 Battery Current Charge Monitor DCM2-DIFA14 352 8 Battery Current Discharge Monitor DCM2-DIFA15 360 304 Magnetometer Data DCM2-SD3 664 168 EPAM Data DCM1-SD0 832 464 CRIS Data DCM2-SD0 -------------- ------ ---------------------------------------------- ----------- 1296 1992 SIS Data DCM2-SD1 3288 544 SWEPAM Ion Data DCM1-SD2 3832 456 SWEPAM Electron Data DCM2-SD2 4288 1000 ULEIS Data DCM1-SD1 5288 1624 S^3 DPU Data DCM1-SD3 -------------- ------ ---------------------------------------------- ----------- Science Format Minor Frame 6 Location Length Parameter Source -------------- ------ ---------------------------------------------- ----------- 6912 32 Command Link Control Word C&DH 6944
-------------- ------ ---------------------------------------------- -----------Science Format Minor Frame 7 Location Length Parameter Source -------------- ------ ---------------------------------------------- ----------- 0 32 Sync Word C&DH 32 48 Virtual Channel Header C&DH 80 48 Packet Header C&DH 128 32 Packet Secondary Header C&DH 160 4 Format ID C&DH -------------- ------ ---------------------------------------------- ----------- 164 2 Spare 166 2 C&DH ID C&DH 168 1 Collection Format C&DH 169 3 Major Frame Count C&DH 172 4 Minor Frame Count C&DH -------------- ------ ---------------------------------------------- ----------- 176 8 Selectable Telemetry Byte C&DH 184 16 Phase Angle latched in collected minor frame 7 C&DH 200 128 Power Subsystem Redundant Proc. Data- 2x Major DCM2-SD7 328 8 Battery Temperature 1: Top of Center Cell DCM2-AD2 336 8 Battery Temperature 2: Top of Cell at +Z End DCM2-AD3 -------------- ------ ---------------------------------------------- ----------- 344 8 Heater-Battery A&B Current DCM2-DIFA16 352 8 Battery Voltage DCM2-SEA4 360 304 Magnetometer Data DCM2-SD3 664 168 EPAM Data DCM1-SD0 832 464 CRIS Data DCM2-SD0 -------------- ------ ---------------------------------------------- ----------- 1296 1992 SIS Data DCM2-SD1 3288 544 SWEPAM Ion Data DCM1-SD2 3832 456 SWEPAM Electron Data DCM2-SD2 4288 1000 ULEIS Data DCM1-SD1 5288 1624 S^3 DPU Data DCM1-SD3 -------------- ------ ---------------------------------------------- ----------- Science Format Minor Frame 7 Location Length Parameter Source -------------- ------ ---------------------------------------------- ----------- 6912 32 Command Link Control Word C&DH 6944
-------------- ------ -------------------------------------------------------------------------------- -------------Science Format Minor Frame 8 Location Length Parameter Source -------------- ------ -------------------------------------------------------------------------------- ------------- 0 32 Sync Word C&DH 32 48 Virtual Channel Header C&DH 80 48 Packet Header C&DH 128 32 Packet Secondary Header C&DH 160 4 Format ID C&DH -------------- ------ -------------------------------------------------------------------------------- ------------- 164 2 Spare C&DH 166 2 C&DH ID C&DH 168 1 Collection Format C&DH 169 3 Major Frame Count C&DH 172 4 Minor Frame Count C&DH -------------- ------ -------------------------------------------------------------------------------- ------------- 176 8 Selectable Telemetry Byte C&DH 184 16 Phase Angle latched in collected minor frame 8 C&DH 200 8 Transponder A Receiver Current DCM2-DIFA9 208 8 Pre-Mod Conditioner & Transmitter A Current DCM2-DIFA10 216 8 Transponder B Receiver Current DCM2-DIFA11 -------------- ------ -------------------------------------------------------------------------------- ------------- 224 8 Pre-Mod Conditioner & Transmitter B Current DCM2-DIFA12 232 8 Transponder A Receiver AGC DCM2-SEA7 240 8 Transponder A Receiver SPE DCM2-SEA8 248 8 Transponder A Receiver +5V DCM2-SEA9 256 8 Transponder B Receiver AGC DCM2-SEA10 -------------- ------ -------------------------------------------------------------------------------- ------------- 264 8 Transponder B Receiver SPE DCM2-SEA11 272 8 Transponder B Receiver +5V DCM2-SEA12 280 8 Transmitter Power Converter Temp (not x-strapped) DCM2-AD0 288 8 Transmitter Power Amplifier Temp (not x-strapped) DCM2-AD1 296 8 Transponder Transmitter RF power level (not x-strapped) DCM2-SEA13 -------------- ------ -------------------------------------------------------------------------------- ------------- Science Format Minor Frame 8 Location Length Parameter Source -------------- ------ -------------------------------------------------------------------------------- ------------- 304 1 Trpndr B antenna SW #2 to +Z - C&DH A only DCM2-DIGTTSW7 305 1 Trpndr B antenna SW #1 to -Z Axis - C&DH A only DCM2-DIGTTSW6 306 1 Trnpdr A antenna SW #2 to +Z - C&DH A only DCM2-DIGTTSW5 307 1 Trpndr A antenna SW #1 to-Z Axis - C&DH A only DCM2-DIGTTSW4 308 1 PS Latch Valve B2 Open - C&DH A only DCM2-DIGTTSW3 -------------- ------ -------------------------------------------------------------------------------- ------------- 309 1 PS Latch Valve B1 Open - C&DH A only DCM2-DIGTTSW2 310 1 PS Latch Valve A2 Open - C&DH A only DCM2-DIGTTSW1 311 1 PS Latch Valve A1 Open - C&DH A only DCM2-DIGTTSW0 312 8 Pre-Mod Conditioner +5V (not x-strapped) DCM2-SEA14 320 8 Propellant Pressure A DCM2-SEA5 -------------- ------ -------------------------------------------------------------------------------- ------------- 328 8 Propellant Pressure B DCM2-SEA6 336 24 "Last SP TT = 4 Mnr Frame bits, 10 subsec count bits, 2 ID bits, 8 Y-angle bits" C&DH 360 304 Magnetometer Data DCM2-SD3 664 168 EPAM Data DCM1-SD0 832 464 CRIS Data DCM2-SD0 -------------- ------ -------------------------------------------------------------------------------- ------------- 1296 1992 SIS Data DCM2-SD1 3288 544 SWEPAM Ion Data DCM1-SD2 3832 456 SWEPAM Electron Data DCM2-SD2 4288 1000 ULEIS Data DCM1-SD1 5288 1624 S^3 DPU Data DCM1-SD3 -------------- ------ -------------------------------------------------------------------------------- ------------- 6912 32 Command Link Control Word C&DH 6944
-------------- ------ ------------------------------------------------------ ----------Science Format Minor Frame 9 Location Length Parameter Source -------------- ------ ------------------------------------------------------ ---------- 0 32 Sync Word C&DH 32 48 Virtual Channel Header C&DH 80 48 Packet Header C&DH 128 32 Packet Secondary Header C&DH 160 4 Format ID C&DH -------------- ------ ------------------------------------------------------ ---------- 164 2 Spare C&DH 166 2 C&DH ID C&DH 168 1 Collection Format C&DH 169 3 Major Frame Count C&DH 172 4 Minor Frame Count C&DH -------------- ------ ------------------------------------------------------ ---------- 176 8 Selectable Telemetry Byte C&DH 184 16 Phase Angle latched in collected minor frame 9 C&DH 200 8 SWEPAM(E) +8V PSMON - Subcom over 8 major frames DCM1-SEA0 208 8 SWEPAM(E) HVMON1 - Subcom over 8 major frames DCM1-SEA1 216 8 SWEPAM(E) HVMON2 - Subcom over 8 major frames DCM1-SEA2 -------------- ------ ------------------------------------------------------ ---------- 224 8 SWEPAM(I) +8V PSMON - Subcom over 8 major frames DCM1-SEA3 232 8 SWEPAM(I) HVMON1 - Subcom over 8 major frames DCM1-SEA4 240 8 SWEPAM(I) HVMON2 - Subcom over 8 major frames DCM1-SEA5 248 8 EPAM Analog A1 Int/Ext Cal Readout DCM1-SEA6 256 8 "EPAM Analog A2, Subcom over 8 major frames" DCM1-SEA7 -------------- ------ ------------------------------------------------------ ---------- 264 8 "EPAM Analog A3, Subcom over 8 major frames" DCM1-SEA8 272 8 EPAM Analog A4 Input Current Monitor DCM1-SEA9 280 8 EPAM LAN 1 Electronics Temperature - Thermistor DCM1-SEA10 288 8 EPAM LAN 2A Electronics Temperature - Thermistor DCM1-SEA11 296 8 EPAM LAN 2B Sensor Temperature - Thermistor DCM1-SEA12 -------------- ------ ------------------------------------------------------ ---------- Science Format Minor Frame 9 Location Length Parameter Source -------------- ------ ------------------------------------------------------ ---------- 304 8 ULEIS LVPS Voltage DCM1-SEA13 312 8 CRIS Internal Temperature #1 DCM1-AD14 320 8 CRIS Internal Temperature #2 DCM1-AD15 328 8 SIS Internal Temperature #1 DCM1-AD17 336 8 SIS Internal Temperature #2 DCM1-AD18 -------------- ------ ------------------------------------------------------ ---------- 344 16 Phase angle latched with Sun Pulse TT in minor frame 0 C&DH 360 304 Magnetometer Data DCM2-SD3 664 168 EPAM Data DCM1-SD0 832 464 CRIS Data DCM2-SD0 1296 1992 SIS Data DCM2-SD1 -------------- ------ ------------------------------------------------------ ---------- 3288 544 SWEPAM Ion Data DCM1-SD2 3832 456 SWEPAM Electron Data DCM2-SD2 4288 1000 ULEIS Data DCM1-SD1 5288 1624 S^3 DPU Data DCM1-SD3 6912 32 Command Link Control Word C&DH -------------- ------ ------------------------------------------------------ ---------- 6944
-------------- ------ ---------------------------------------------------- --------------Science Format Minor Frame 10 Location Length Parameter Source -------------- ------ ---------------------------------------------------- -------------- 0 32 Sync Word C&DH 32 48 Virtual Channel Header C&DH 80 48 Packet Header C&DH 128 32 Packet Secondary Header C&DH 160 4 Format ID C&DH -------------- ------ ---------------------------------------------------- -------------- 164 2 Spare C&DH 166 2 C&DH ID C&DH 168 1 Collection Format C&DH 169 3 Major Frame Count C&DH 172 4 Minor Frame Count C&DH -------------- ------ ---------------------------------------------------- -------------- 176 8 Selectable Telemetry Byte C&DH 184 16 Phase Angle latched in collected minor frame 10 C&DH 200 8 Solid State Recorder A DCDCOUT DCM1-SEA16 208 8 Solid State Recorder B DCDCOUT DCM1-SEA17 216 1 DCM1 - Digital Telltale-Switch Channel #15 DCM1-DIGTTSW15 -------------- ------ ---------------------------------------------------- -------------- 217 1 SIS Cover Telltale DCM1-DIGTTSW14 218 1 S3DPU Power Converter Select TT DCM1-DIGTTSW13 219 1 SWIMS Cover Telltale DCM1-DIGTTSW12 220 1 Redundant Charger Selected TT DCM1-DIGTTSW11 221 1 Prime Charger Selected TT DCM1-DIGTTSW10 -------------- ------ ---------------------------------------------------- -------------- 222 1 Redundant Shunt Electronics Selected TT DCM1-DIGTTSW9 223 1 Prime Shunt Electronics Selected TT DCM1-DIGTTSW8 224 8 "CRIS, I/F, & Survival Heater Current " DCM1-DIFA15 232 8 "SIS, I/F, & Survival Heater Current " DCM1-DIFA16 240 8 EPAM Electronics & I/F Heater Current DCM1-DIFA17 -------------- ------ ---------------------------------------------------- -------------- Science Format Minor Frame 10 Location Length Parameter Source -------------- ------ ---------------------------------------------------- -------------- 248 8 EPAM Survival/Operational Heater Current DCM1-DIFA18 256 8 ULEIS & Survival Heater Current DCM1-DIFA19 264 8 ULEIS Analog Elect. LVPS Current DCM1-DIFA20 272 8 DCM1 - 0-50mV Channel #21 DCM1-DIFA21 280 8 ULEIS Internal & I/F Heater Current DCM1-DIFA22 -------------- ------ ---------------------------------------------------- -------------- 288 8 SWEPAM Electron Current DCM1-DIFA23 296 8 SWEPAM Ion Current DCM1-DIFA24 304 8 "SWIMS, I/F, & Survival Htr Current" DCM1-DIFA25 312 8 "SWICS, I/F, and Survival Htr Current" DCM1-DIFA26 320 8 "SEPICA, I/F, & Survival Htr Current" DCM1-DIFA27 -------------- ------ ---------------------------------------------------- -------------- 328 8 Magnetometer Electronics and Survival Heater Current DCM1-DIFA28 336 8 S^3 DPU Current DCM1-DIFA29 344 8 Heater-Prop. System Deck Primary Current DCM1-DIFA12 352 8 Heater-Prop. System Deck Backup Current DCM1-DIFA13 360 304 Magnetometer Data DCM2-SD3 -------------- ------ ---------------------------------------------------- -------------- 664 168 EPAM Data DCM1-SD0 832 464 CRIS Data DCM2-SD0 1296 1992 SIS Data DCM2-SD1 3288 544 SWEPAM Ion Data DCM1-SD2 3832 456 SWEPAM Electron Data DCM2-SD2 -------------- ------ ---------------------------------------------------- -------------- 4288 1000 ULEIS Data DCM1-SD1 5288 1624 S^3 DPU Data DCM1-SD3 6912 32 Command Link Control Word C&DH 6944
-------------- ------ -------------------------------------------------------- --------------Science Format Minor Frame 11 Location Length Parameter Source -------------- ------ -------------------------------------------------------- -------------- 0 32 Sync Word C&DH 32 48 Virtual Channel Header C&DH 80 48 Packet Header C&DH 128 32 Packet Secondary Header C&DH 160 4 Format ID C&DH -------------- ------ -------------------------------------------------------- -------------- 164 2 Spare C&DH 166 2 C&DH ID C&DH 168 1 Collection Format C&DH 169 3 Major Frame Count C&DH 172 4 Minor Frame Count C&DH -------------- ------ -------------------------------------------------------- -------------- 176 8 Selectable Telemetry Byte C&DH 184 16 Phase Angle latched in collected minor frame 11 C&DH 200 112 "Power Switching, Ordnance Fire Relay Telltales" DCM1-SD5 319 1 S3 DPU Interface A/B Select DCM1-DIGTTLOG7 318 1 Transponder B Transmitter On/Off DCM1-DIGTTLOG6 -------------- ------ -------------------------------------------------------- -------------- 317 1 Transponder B Receiver In-lock/Out-lock DCM1-DIGTTLOG5 316 1 Transponder A Transmitter On/Off DCM1-DIGTTLOG4 315 1 Transponder A Receiver In-lock/Out-Lock DCM1-DIGTTLOG3 314 1 Transponder Aux Osc On/Off (not x-strapped) DCM1-DIGTTLOG2 313 1 Transponder Transmitter Mod Index Hi/Lo (not x-strapped) DCM1-DIGTTLOG1 -------------- ------ -------------------------------------------------------- -------------- 312 1 Transponder Ranging Channel On/Off (not x-strapped) DCM1-DIGTTLOG0 320 8 DCM1 - 0-5V Channel #18 DCM1-SEA18 328 8 "OAF Temperature: +X Octant, Near PAF Interface" DCM1-PT27 336 8 Aft Deck Temperature: Between Ant Foot and SLAM DCM1-PT28 344 8 S^3 DPU Converter Secondary Current DCM1-DIFA30 -------------- ------ -------------------------------------------------------- -------------- Science Format Minor Frame 11 Location Length Parameter Source -------------- ------ -------------------------------------------------------- -------------- 352 8 Pressure Transducer #1 & #2 Current DCM1-DIFA14 360 304 Magnetometer Data DCM2-SD3 664 168 EPAM Data DCM1-SD0 832 464 CRIS Data DCM2-SD0 1296 1992 SIS Data DCM2-SD1 -------------- ------ -------------------------------------------------------- -------------- 3288 544 SWEPAM Ion Data DCM1-SD2 3832 456 SWEPAM Electron Data DCM2-SD2 4288 1000 ULEIS Data DCM1-SD1 5288 1624 S^3 DPU Data DCM1-SD3 6912 32 Command Link Control Word C&DH -------------- ------ -------------------------------------------------------- -------------- 6944
-------------- ------ ----------------------------------------------- ---------Science Format Minor Frame 12 Location Length Parameter Source -------------- ------ ----------------------------------------------- --------- 0 32 Sync Word C&DH 32 48 Virtual Channel Header C&DH 80 48 Packet Header C&DH 128 32 Packet Secondary Header C&DH 160 4 Format ID C&DH -------------- ------ ----------------------------------------------- --------- 164 2 Spare C&DH 166 2 C&DH ID C&DH 168 1 Collection Format C&DH 169 3 Major Frame Count C&DH 172 4 Minor Frame Count C&DH -------------- ------ ----------------------------------------------- --------- 176 8 Selectable Telemetry Byte C&DH 184 16 Phase Angle latched in collected minor frame 12 C&DH 200 8 SWIMS Internal Temperature DCM1-AD5 208 8 SWICS Internal Temperature DCM1-AD7 216 8 ULEIS Telescope Temperature DCM1-AD9 -------------- ------ ----------------------------------------------- --------- 224 8 ULEIS Analog Electronics Temperature (Internal) DCM1-AD10 232 8 ULEIS DPU Temperature (Internal) DCM1-AD11 240 8 SEPICA Iso-Butane Tank Temperature DCM1-AD20 248 8 S^3 DPU Power Supply A Temperature DCM1-AD22 256 8 SWEPAM(E) Internal Temperature DCM1-AD24 -------------- ------ ----------------------------------------------- --------- 264 8 SWEPAM(I) Internal Temperature DCM1-AD26 272 64 Last Star Scanner Data DCM1-SD6 336 8 Terminal Board #1/Fuse Temperature DCM1-AD28 344 8 Instrument Deck Temperature (TBD) #1 DCM1-AD29 352 8 S^3 DPU Power Supply B Temperature DCM1-AD30 -------------- ------ ----------------------------------------------- --------- Science Format Minor Frame 12 Location Length Parameter Source -------------- ------ ----------------------------------------------- --------- 360 304 Magnetometer Data DCM2-SD3 664 168 EPAM Data DCM1-SD0 832 464 CRIS Data DCM2-SD0 1296 1992 SIS Data DCM2-SD1 3288 544 SWEPAM Ion Data DCM1-SD2 -------------- ------ ----------------------------------------------- --------- 3832 456 SWEPAM Electron Data DCM2-SD2 4288 1000 ULEIS Data DCM1-SD1 5288 1624 S^3 DPU Data DCM1-SD3 6912 32 Command Link Control Word C&DH 6944
-------------- ------ ----------------------------------------------- --------Science Format Minor Frame 13 Location Length Parameter Source -------------- ------ ----------------------------------------------- -------- 0 32 Sync Word C&DH 32 48 Virtual Channel Header C&DH 80 48 Packet Header C&DH 128 32 Packet Secondary Header C&DH 160 4 Format ID C&DH -------------- ------ ----------------------------------------------- -------- 164 2 Spare C&DH 166 2 C&DH ID C&DH 168 1 Collection Format C&DH 169 3 Major Frame Count C&DH 172 4 Minor Frame Count C&DH -------------- ------ ----------------------------------------------- -------- 176 8 Selectable Telemetry Byte C&DH 184 16 Phase Angle latched in collected minor frame 13 C&DH 200 160 Bits 0 to 159 of active C&DH housekeeping data C&DH 360 304 Magnetometer Data DCM2-SD3 664 168 EPAM Data DCM1-SD0 -------------- ------ ----------------------------------------------- -------- 832 464 CRIS Data DCM2-SD0 1296 1992 SIS Data DCM2-SD1 3288 544 SWEPAM Ion Data DCM1-SD2 3832 456 SWEPAM Electron Data DCM2-SD2 4288 1000 ULEIS Data DCM1-SD1 -------------- ------ ----------------------------------------------- -------- 5288 1624 S^3 DPU Data DCM1-SD3 6912 32 Command Link Control Word C&DH 6944
-------------- ------ ------------------------------------------------ --------Science Format Minor Frame 14 Location Length Parameter Source -------------- ------ ------------------------------------------------ -------- 0 32 Sync Word C&DH 32 48 Virtual Channel Header C&DH 80 48 Packet Header C&DH 128 32 Packet Secondary Header C&DH 160 4 Format ID C&DH -------------- ------ ------------------------------------------------ -------- 164 2 Spare C&DH 166 2 C&DH ID C&DH 168 1 Collection Format C&DH 169 3 Major Frame Count C&DH 172 4 Minor Frame Count C&DH -------------- ------ ------------------------------------------------ -------- 176 8 Selectable Telemetry Byte C&DH 184 16 Phase Angle latched in collected minor frame 14 C&DH 200 160 Bits 160 to 319 of active C&DH housekeeping data C&DH 360 304 Magnetometer Data DCM2-SD3 664 168 EPAM Data DCM1-SD0 -------------- ------ ------------------------------------------------ -------- 832 464 CRIS Data DCM2-SD0 1296 1992 SIS Data DCM2-SD1 3288 544 SWEPAM Ion Data DCM1-SD2 3832 456 SWEPAM Electron Data DCM2-SD2 4288 1000 ULEIS Data DCM1-SD1 -------------- ------ ------------------------------------------------ -------- 5288 1624 S^3 DPU Data DCM1-SD3 6912 32 Command Link Control Word C&DH 6944
-------------- ------ ------------------------------------------------------ ---------Science Format Minor Frame 15 Location Length Parameter Source -------------- ------ ------------------------------------------------------ --------- 0 32 Sync Word C&DH 32 48 Virtual Channel Header C&DH 80 48 Packet Header C&DH 128 32 Packet Secondary Header C&DH 160 4 Format ID C&DH -------------- ------ ------------------------------------------------------ --------- 164 2 Spare C&DH 166 2 C&DH ID C&DH 168 1 Collection Format C&DH 169 3 Major Frame Count C&DH 172 4 Minor Frame Count C&DH -------------- ------ ------------------------------------------------------ --------- 176 8 Selectable Telemetry Byte C&DH 184 16 Phase Angle latched in collected minor frame 15 C&DH 200 64 Bits 320-383 of bits of active C&DH housekeeping data C&DH 264 8 Analog Shunt Panel Temperature DCM1-PT23 272 8 Aft Deck Temperature (TBD) #1 DCM1-PT24 -------------- ------ ------------------------------------------------------ --------- 280 64 Opposite C&DH Component Hskp Data DCM1-SD4 344 16 Phase angle latched with Sun Pulse TT in minor frame 8 C&DH 360 304 Magnetometer Data DCM2-SD3 664 168 EPAM Data DCM1-SD0 832 464 CRIS Data DCM2-SD0 -------------- ------ ------------------------------------------------------ --------- 1296 1992 SIS Data DCM2-SD1 3288 544 SWEPAM Ion Data DCM1-SD2 3832 456 SWEPAM Electron Data DCM2-SD2 4288 1000 ULEIS Data DCM1-SD1 5288 1624 S^3 DPU Data DCM1-SD3 -------------- ------ ------------------------------------------------------ --------- Science Format Minor Frame 15 Location Length Parameter Source -------------- ------ ------------------------------------------------------ --------- 6912 32 Command Link Control Word C&DH 6944