Solar Energetic Particle Fluences					
November 6, 1997 Event					
Based on Data from ACE/EPAM; GOES-8,11,&12; and SAMPEX/PET					
					
Note: Statistical Uncertainties on GOES andEPAM data are negligible.					
To account for systematic uncertainties in combining data from different					
   sensors we add 20% in quadrature with the statistical uncertainties					
					
Fluence Spectra					
Start: 	1200 UT on 11/6/97				
End:	2400 UT on 11/9/97				
					
Compiled by R. A. Mewaldt (RMewaldt@srl.caltech.edu)					
	with help from Mark Looper, Christina Cohen, and Dennis Haggerty				
					
			    Statistical		
Z	E	Fluence		Sigma		20% sigma	Instrument
1	0.0442	1.58E+10			3.16E+09	EPAM
1	0.0714	6.91E+09			1.38E+09	
1	0.1264	3.61E+09			7.22E+08	
1	0.2169	1.38E+09			2.76E+08	
1	0.3922	5.75E+08			1.15E+08	
1	0.741	2.28E+08			4.56E+07	
1	1.36	8.87E+07			1.77E+07	
1	2.93	2.72E+07			5.44E+06	
					
1	17.32	1.16E+06			2.32E+05	GOES11-Int
1	38.73	3.07E+05			6.14E+04	
1	54.77	1.52E+05			3.04E+04	
1	77.46	6.16E+04			1.23E+04	
					
1	6.00	5.90E+06			1.18E+06	GOES-11-Diff
1	11.6	2.03E+06			4.06E+05	
1	24.5	1.00E+06			2.00E+05	
1	56.6	1.47E+05			2.94E+04	
1	114.9	1.90E+04			3.80E+03	
					
1	20.02	9.17E+05	2.10E+04	1.85E+05	PET
1	22.13	8.12E+05	1.85E+04	1.63E+05	
1	24.18	6.91E+05	1.81E+04	1.39E+05	
1	26.28	7.83E+05	1.84E+04	1.58E+05	
1	32.01	4.15E+05	6.75E+03	8.33E+04	
1	41.39	2.82E+05	7.25E+03	5.69E+04	
1	49.27	1.41E+05	5.62E+03	2.88E+04	
1	58.78	1.22E+05	4.41E+03	2.48E+04	
1	67.8	9.40E+04	4.59E+03	1.94E+04	
1	73.25	6.79E+04	4.12E+03	1.42E+04	
1	80.5	5.87E+04	3.40E+03	1.22E+04	
1	101.1	3.50E+04	1.93E+03	7.26E+03	
1	154.9	1.47E+04	8.78E+02	3.07E+03	
1	245.0	4.17E+03	4.60E+02	9.52E+02	 
1	387.3	1.17E+03	1.90E+02	3.01E+02