Solar Energetic Particle Fluences					
November 4, 2001 Event					
Based on Data from ACE/EPAM; GOES-8,11,&12; and SAMPEX/PET					
					
Note: Statistical Uncertainties on GOES and EPAM data are negligible.					
To account for systematic uncertainties in combining data from different					
   sensors we add 20% in quadrature with the statistical uncertainties					
					
Fluence Spectra					
Start: 	0500 UT on 11/4/2001				
End:	2400 UT on 11/12/01				
					
Compiled by R. A. Mewaldt (RMewaldt@srl.caltech.edu)					
	with help from Mark Looper, Christina Cohen, and Dennis Haggerty				
					
				Statistical		
Z	E	Fluence		Sigma		20% sigma	Instrument
1	0.0853	5.10E+10	Negligible	1.02E+10	EPAM
1	0.145	3.15E+10	Negligible	6.30E+09	
1	0.241	1.27E+10	Negligible	2.54E+09	
1	0.424	6.77E+09	Negligible	1.35E+09	
1	0.784	3.66E+09	Negligible	7.32E+08	
1	1.42	1.83E+09	Negligible	3.66E+08	
1	3.01	6.47E+08	Negligible	1.29E+08	
					
1	17.3	4.65E+07	Negligible	9.30E+06	GOES8-Int
1	38.7	9.58E+06	Negligible	1.92E+06	
1	54.8	3.99E+06	Negligible	7.98E+05	
1	77.5	7.65E+05	Negligible	1.53E+05	
					
1	11.6	7.75E+07	Negligible	1.55E+07	GOES8-Diff
1	24.5	3.75E+07	Negligible	7.50E+06	
1	56.6	3.72E+06	Negligible	7.44E+05	
1	114.9	8.27E+04	Negligible	1.65E+04	
					
1	20.0	2.95E+07	8.51E+05	5.96E+06	PET
1	22.1	2.61E+07	7.64E+05	5.28E+06	
1	24.2	2.38E+07	7.64E+05	4.82E+06	
1	26.3	2.45E+07	7.22E+05	4.95E+06	
1	32.0	1.19E+07	2.38E+05	2.39E+06	
1	41.4	4.52E+06	1.88E+05	9.23E+05	
1	49.3	3.57E+06	2.04E+05	7.43E+05	
1	58.8	2.38E+06	1.40E+05	4.96E+05	
1	67.8	2.18E+06	4.86E+05	6.53E+05	
1	73.3	1.74E+06	3.95E+05	5.26E+05	
1	80.5	1.55E+06	3.09E+05	4.38E+05